On 15/05/2024 05:52, Moses Browne Mwakyanjala wrote:
The on-board clock on a B210 is good to about 2.5PPM. So, it's working as you would expect.I've encountered a consistent frequency offset of around 2ppm with my new B210. Operating at a sample rate of 4 MSPS with the "internal" clock, all calibrations were performed using a sine wave from an Agilent signal generator.
Though seemingly minor, the 800Hz offset at UHF poses challenges in receiving low-rate data from orbiting satellites. Is there an automated method to approximate and mitigate this offset? Currently, I manually adjust the frequency by subtracting the offset in ppm. However, I'm curious if there are more sophisticated solutions available, excluding reliance on GPS or a 10MHz reference.
Best regards,
Moses
There's nothing built in to the UHD API for this, because normally, if you care about clock accuracy beyond what the internal clock
can supply, you use an external, better, clock. GPSDOs are not very expensive these days, and you can pick up used
10MHz OCXO units fairly cheaply as well...