Hei Wei,
Try adding a Throttle block to the upper branch too. A quick test shows that if you have two independent data flow paths, the sample rate will be way too high (see log output in the lower left corner: rate is at 300 MS/s
Compare this to the same flowgraph with added throttle in the upper branch:
Now the sample rate is as expected at 32k.
Hope this helps in finding your issue!
-Adrian
From: discuss-gnuradio-bounces+adrian.winter=sintef.no@gnu.org <discuss-gnuradio-bounces+adrian.winter=sintef.no@gnu.org> On Behalf Of Huang Wei
Sent: fredag 3. mai 2024 12:55
To: GNURadio Discussion List <discuss-gnuradio@gnu.org>
Subject: Period doesn't match for frequency sweeping using probe
Hello GNURadio community,
I am trying to generate a sweeping frequency signal. I use a probe to detect a Triangle signal with 1 s period, and measure the level using function probe.
Then I set the frequency of the signal source to 10e6 * func_probe, hoping it starts to sweep from -5e6 to 5e6 Hz with 1 s period. It does sweep between -5e6-5e6 Hz, but with much faster period than 1 s. Could you please help me to figure out where is the problem for the period mismatch?
Thank you very much!
Wei
Read the mailing list of the GNU project right here! The information here is regarding the GNU radio project for USRP radios.
Friday, May 3, 2024
Re: Period doesn't match for frequency sweeping using probe
Hi Adrian and Marcus,
That solved the problem : )
Thank you very much for your help!
Kind regards,
Wei