On 4/30/24 18:35, Gary Schafer wrote:
> "I need data points at convenient intervals for time series plotting,
> e.g., 512 samples/second going into a 512 bin FFT to provide one maximum
> amplitude value per second."
>
> Let me answer that one at the same time as "Ultimately I want to plot
> both the amplitude and any frequency change to sub-Hz resolution."
>
> Okay, you've hit a contradiction. You can NOT get "sub-Hz" resolution
> using a sample rate, in Hz, that equals your time record size, in
> samples.
Hi Gary -- sorry if my message was confusing. I do understand the
relationships between sample rate, FFT depth, time resolution, and
frequency resolution. I used 512 samples/512 bins/1 second as a simple
test case for the problem that I'm not getting one data point per frame,
regardless of the frame rate. Given how noisy this data is, I may well
end up with something like one frame per 10 seconds, but before I can
play with that I need to understand what is wrong with my processing to
get the amplitude of the maximum bin per frame.
John
No comments: