Thursday, June 10, 2021

Re: Phase Synchronize 2 USRP N200 w/ SBX cards

On 06/10/2021 01:00 PM, Skyvalakis Konstantinos wrote:

In addition to my last message regarding the INTEGER_N tuning​, ​I repeated the experiment multiple times. I even restarted the USRPs and the signal generator multiple times.


What I observed was, that there were only 4 different recurring phase offsets (Blue = RX2 of SBX1, Red = RX2 of SBX2).


I am attaching the 4 screenshots I captured.


Thank you so much for your help. I feel like we're getting there.




You're sure that you have SBX cards and not WBX cards?  Sorry for the apparently-stupid question, but the WBX uses almost the
  same hardware as the SBX, but uses a 2XLO mixer that has fixed phase ambiguity--which would look like what you have here.