Hi Ali,
One way to achieve this would be to use a "Head" block with the "Num Items" set to: samp_rate*2.
Then set the values under the top_block/Options block to be:
Generate Options: No GUI
Run Options: Run to Completion.
Regards,
Nate
> On Apr 27, 2017, at 2:30 AM, do ber <03dober@gmail.com> wrote:
>
> Hi to all,
>
> I want to get I/Q samples from USRP via UHD Source and then write them to a file via File Sink.But I want to record 2 seconds of length samples. After 2 seconds I want the program stop running.
>
> Is that possible? How?
>
> Best,
> Ali